Page 18 - AB007_感測器原理與應用實習
P. 18

第   章   感測課程前置作業            基本知識複習

























                            (a)分壓器                                     (b)阻值調整
                                            圖 1-5  分壓器與阻值調整

                       若     Rv =10     ,被調整為R x =200 ,R y =9.8                ,而V ref =12

                             I 2 =1   時,I 1 × R x + I 3 × R y =12 ,又I 1 = I 2 + I 3

                       則     1     + I 3 × 200 + I 3 × 9.8 =12
                            I 3 =1.18    ,I 1 =2.18

                           R x 的功率損耗           P RX = 1.18     2 × 200 =0.28        <250

                           R y 的功率損耗           P Ry = 2.18     2  × 9.8  = 46.6      <250
                       若 I 2 =50       時,

                            50     + I 3 × 200 + I 3 × 9.8 =12

                           I 3 =0.2    ,I 1 =50.2

                           R x 的功率損耗           R R =(50.2      2  × 200 = 504      >250
                           R y 的功率損耗           R Ry = 0.2     2 × 9.8 =0.392       <250

                       就在I 2 =50         的時候可變電阻上半部R x 200 ) 的功率損耗

                 P Rx =504      ,遠大於安全規格 1/4W(250mW),會把R x 部份燒掉,

                 則整個可變電阻等於完全損壞而無法使用。




                               總結:不要讓可變電阻中點流經太大的電流。

                                      使用前請先算一下。
   13   14   15   16   17   18   19   20   21   22   23